Skip to Main Content
Cloud Management and AIOps


This is an IBM Automation portal for Cloud Management, Technology Cost Management, Network Automation and AIOps products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).

Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.

Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Clear

Ideas

Showing 240 of 6126

Custom Template Sensor - executeCommandWithTimeout (may) block if standard input is not redirected from a file

The executeCommandWithTimeout command (may) block if standard input is not redirected from a file. The command we are executing does not as far as I can tell read from standard input, so I don't really understand why this is happening). We redirec...
over 8 years ago in Tivoli Application Dependency Discovery Manager 1 Is a defect

Custom Template Sensor - executeCommandWithTimeout does not handle standard error

The jython executeCommandWithTimeout does not handle standard error. We had to redirect stderr to stdout to see anything written on stderr. The output on stderr should be logged by default.
over 8 years ago in Tivoli Application Dependency Discovery Manager 1 Not under consideration

Huawei Network Device Discovery Sensor

Hi Team, cannot see any of Huawei devices as supported target in reference document.Since TADDM doesn't have sensors for Huawei so How TADDM going to discover ?Secondly, may be you trying to say lets try with snmp see the result and if attributes ...
over 5 years ago in Tivoli Application Dependency Discovery Manager 2 Not under consideration

Oracle Exacc Discovery enablement

We are not able to enable TADDM discovery for oracle Exacc in the current version of TADDM 7.3 FP3 . Could you please kindly build a new customized oracle Exacc sensor which helps us to enable the discovery for the same.
almost 6 years ago in Tivoli Application Dependency Discovery Manager 0 Planned for future release

Need to create alert based on trace / http metric value

create a custom alert (and thus event in the first instance) in our Production Instana instance.EVENT: The application is "Card Services" the metric is "Call latency" (P99) and the filter I'm trying to apply is on call.http.path that equals a spec...
about 6 years ago in Instana / Alert 0 Functionality already exists

Reference-able filter of infrastructure entities

User story As an Instana user,who is in the process of specifying a filter on a set of infrastructure entities,in order to view these entities, to detect issues on them, or to configure maintenance windows on them, I want to have a way to persist ...
almost 2 years ago in Instana / Access Control / Alert / Infrastructure 0 Planned for future release

Need ability to select single event with multiple threshold on same metric for different disk mount

Currently in Instana you cannot create more than one threshold on same metric. We get this message "No more than one threshold can be defined on the same metric." Use case: Customer wants to create a single event when disk mount usage exceeds 90% ...
about 2 years ago in Instana / Alert 3 Not under consideration

Require Alert Time Window Condition for more than 120 min

We have a custom MQ alert to create an alarm, if messages are not received for more than 12 hours in IBM APM. We have created similar alert in Instana, however alert time window condition is not allowing to add condition of more than 120 mins. We ...
about 2 years ago in Instana / Alert 1 Not under consideration

Define custom alert for MQ Last put time like IBM APM

We have similar event in IBM APM solution and Instana is collecting the same metrics but cannot define custom alert on the same (Last put time not showing in custom alert). Instana infrastructure don’t support to use non metrics data(numeric) as c...
about 2 years ago in Instana / Alert / Sensor 1 Not under consideration

Add email in CC as alert channel

Operation team keeps tracks of who is receiving the alert, at the moment once there is an alert, single emails are sent to each email. It would be preferable to have a main email and a list of emails in CC.
about 2 years ago in Instana / Alert 3 Not under consideration